The sag rod restrains the purlin laterally and limits lateral-torsional buckling. It spreads loads between adjacent purlins and increases overall stiffness: in the field or at the ridge, it is essential for long-span structures.

Characteristics
- TubeØ33.7 × 2 mm
- Length1,000 to 2,500 mm, depending on purlin spacing
- SupplyTwo brackets included, one at each end
Benefits
- Lateral stability of purlins during erection and in service
- Limited buckling compression flange restrained
- Even load distribution between adjacent purlins
Applications
- Field line
- Ridge
Scroll to see all columns
| Reference | Description | Weight (kg/m) | Length |
|---|---|---|---|
| Tubular sag rod | Ø33.7 × 2 mm · two brackets included | 1,56 | 1 000 à 2 500 mm |
| Additional bracket | Galvanised steel U bracket with bolts | — | — |
Beyond 9 m span or in wind zone 3, provide at least one line of sag rods in the field, two lines for 12 to 15 m bays. The exact layout is supplied with the EN 1993-1-3 calculation note.