Products
Structural steel and sections
C+ and Z purlins
Plasterboard supports
Solar mounting systems
Liner tray 400/70
Double-skin cladding · 400 mm cover width
Horizontal load-bearing liner tray for double-skin façades. Spanning from column to column, it replaces the girt: no secondary framing is needed. It holds the rock wool insulation and supports the outer profiled-sheet skin.

Characteristics
- SteelS320GD+Z200 · EN 10346
- Cover width400 mm
- Overall height70 mm
Benefits
- Replaces the cladding girt fixed directly to columns
- Holds rock wool between trays
- S320GD+Z200 steel pre-painting on request
Applications
- Industrial and logistics façades
- Buildings with wide column grids
- Double-skin façade renovation
Scroll to see all columns
| Reference | Weight (kg/m²) | Thickness (mm) | Cover width | Height |
|---|---|---|---|---|
| Liner tray 400/70 · 0.75 | 8,98 | 0,75 | 400 mm | 70 mm |
| Liner tray 400/70 · 0.88 | 10,53 | 0,88 | 400 mm | 70 mm |
| Liner tray 400/70 · 1.00 | 11,97 | 1,00 | 400 mm | 70 mm |
Spans given for an L/200 deflection limit; the data sheet also gives the L/150, L/250 and L/300 limits. Outer-skin fixings and local support reaction are to be checked at the level of the cladding system. Reconstructed geometry, to be confirmed by the roll-forming drawing.